资源类型

期刊论文 170

会议视频 6

年份

2023 7

2022 15

2021 13

2020 14

2019 10

2018 6

2017 11

2016 7

2015 31

2014 12

2013 10

2012 6

2011 1

2010 6

2009 6

2008 7

2007 4

2005 3

2004 3

2001 1

展开 ︾

关键词

智能电网 6

可再生能源 3

2021全球十大工程成就 2

海上风电 2

电力系统 2

电网 2

能源 2

10kV高压电力电缆 1

5% 法 1

Cuk矩阵变换器 1

GIC 1

GIS 1

Grid service 1

IEEE 2030.5 1

LM331型电压-频率转换器 1

Visual Basic 6.0 1

Web service 1

中压变频 1

串并联谐振变换器;全桥;半桥;变频;移相;宽范围输入电压 1

展开 ︾

检索范围:

排序: 展示方式:

Multiple target implementation for a doubly fed induction generator based on direct power control under unbalancedand distorted grid voltage

Heng NIAN,Yi-peng SONG

《信息与电子工程前沿(英文)》 2015年 第16卷 第4期   页码 321-334 doi: 10.1631/FITEE.1400170

摘要: This paper presents a multiple target implementation technique for a doubly fed induction generator (DFIG) under unbalanced and distorted grid voltage based on direct power control (DPC). Based on the mathematical model of DFIG under unbalanced and distorted voltage, the proportional and integral (PI) regulator is adopted to regulate the DFIG average active and reactive powers, while the vector PI (VPI) resonant regulator is used to achieve three alternative control targets: (1) balanced and sinusoidal stator current; (2) smooth instantaneous stator active and reactive powers; (3) smooth electromagnetic torque and instantaneous stator reactive power. The major advantage of the proposed control strategy over the conventional method is that neither negative and harmonic sequence decomposition of grid voltage nor complicated control reference calculation is required. The insensitivity of the proposed control strategy to DFIG parameter deviation is analyzed. Finally, the DFIG experimental system is developed to validate the availability of the proposed DPC strategy under unbalanced and distorted grid voltage.

关键词: Direct power control     Doubly fed induction generator     Unbalanced and distorted grid voltage     Vector proportional and integral resonant regulator     Parameter deviation    

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under distortedvoltage conditions

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

《能源前沿(英文)》 2014年 第8卷 第2期   页码 212-220 doi: 10.1007/s11708-013-0284-4

摘要: In this paper, a five-level inverter is used as a shunt active power filter (APF), taking advantages of the multilevel inverter such as low harmonic distortion and reduced switching losses. It is used to compensate reactive power and eliminate harmonics drawn from a thyristor rectifier feeding an inductive load (RL) under distorted voltage conditions. The APF control strategy is based on the use of self-tuning filters (STF) for reference current generation and a fuzzy logic current controller. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the - axis without phase locked loop (PLL). The MATLAB fuzzy logic toolbox is used for implementing the fuzzy logic control algorithm. The obtained results show that the proposed shunt APF controller has produced a sinusoidal supply current with low harmonic distortion and in phase with the line voltage.

关键词: active power filter (APF)     harmonics isolator     distorted voltage conditions     self-tuning filters (STF)     fuzzy logic control    

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

《能源前沿(英文)》 2013年 第7卷 第3期   页码 271-278 doi: 10.1007/s11708-013-0258-6

摘要: A transient model for an induction machine with stator winding turn faults on a single phase is derived using reference frame transformation theory. The negative sequence component and the 3rd harmonic are often considered as accurate indicators. However, small unbalance in the supply voltage and/or in the machine structure that exists in any real system engenders the same harmonics components. In this case, it is too difficult to distinguish between the current harmonics due to the supply voltage and those originated by inter-turn short-circuit faults. For that, to have the correct diagnosis and to increase the sensitivity and the reliability of the diagnostic system, it is crucial to provide the relationship between the inter-turn short-circuits in the stator winding and the supply voltage imbalance through an accurate mathematical model and via a series of experimental essays.

关键词: induction machines     fault indicator     inter-turn short-circuit fault     unbalance supply voltage    

Analysis and stabilization control of a voltage source controlled wind farm under weak grid conditions

《能源前沿(英文)》 2022年 第16卷 第6期   页码 943-955 doi: 10.1007/s11708-021-0793-5

摘要: This paper investigates and discusses the interaction stability issues of a wind farm with weak grid connections, where the wind turbines (WTs) are controlled by a new type of converter control strategy referred to as the voltage source (VS) control. The primary intention of the VS control method is to achieve the high-quality inertial response capability of a single WT. However, when it is applied to multiple WTs within a wind farm, its weak-grid performance regarding the stability remains concealed and needs to be clarified. To this end, a frequency domain model of the wind farm under the VS control is first developed. Based on this model and the application of a stability margin quantification index, not only the interactions between the wind farm and the weak grid but also those among WTs will be systematically assessed in this paper. A crucial finding is that the inertial response of VS control has negative impacts on the stability margin of the system, and the dominant instability mode is more related to the interactions among the WTs rather than the typical grid-wind farm interaction. Based on this knowledge, a stabilization control strategy is then proposed, aiming for stability improvements of VS control while fulfilling the demand of inertial responses. Finally, all the results are verified by time-domain simulations in power systems computer aided design/electromagnetic transients including DC(PSCAD/EMTDC).

关键词: weak grids     voltage source (VS) control     wind turbine (WT)     stabilization control     wind farm     inertial response    

Performance investigation of artificial intelligence based controller for three phase four leg shunt active filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

《能源前沿(英文)》 2015年 第9卷 第4期   页码 446-460 doi: 10.1007/s11708-015-0378-2

摘要: In this paper, the choice of power quality compensator is a DSTATCOM which constitutes a three phase four leg voltage source converter (VSC) with a DC capacitor. The control strategy proposed for the DSTATCOM is a neural network based one cycle control (OCC). This control strategy involves neural network block, digital circuits and linear elements, which eliminates the sensors required for sensing the load current and coupling inductor current in addition to the multiplier employed in the conventional method. The calculation of harmonic and reactive currents for the reference current generation is also eliminated, thus minimizing the complexity in the control strategy. The control strategy mitigates harmonic/reactive currents, ensures balanced and sinusoidal source current from the supply mains that are nearly in phase with the supply voltage, compensates neutral current, and maintains voltage across the capacitor under unbalanced source and load conditions. The performance of the DSTATCOM with the proposed artificial neural network (ANN) controllers is validated and investigated through simulations using Matlab software. The simulation results prove the efficacy of the proposed neural network based control strategy under varying source and load conditions.

关键词: neural network     DSTATCOM     neutral current mitigation     total harmonic distortion (THD)     three phase four wire distribution system     unbalanced and/or distorted source    

Parameter identification of interconnected power system frequency after trip-out of high voltage transmission

Xuzhan ZHOU,Shanshan LIU,Mingkun WANG,Yiping DAI,Yaohua TANG

《能源前沿(英文)》 2014年 第8卷 第3期   页码 386-393 doi: 10.1007/s11708-014-0323-9

摘要: Accurate modeling and parameters of high voltage (HV) grid are critical for stability research of system frequency. In this paper, simulation modeling of the system frequency was conducted of an interconnected power system with HV transmission lines in China. Based on recorded tripping data of the HV transmission lines, system parameters were identified by using genetic algorithm (GA). The favorable agreement between simulation results and recorded data verifies the validity of gird models and the accuracy of system parameters. The results of this paper can provide reference for the stability research of HV power grid.

关键词: high voltage (HV) grid     frequency stability parameter identification     primary frequency regulation (PFR)    

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

《能源前沿(英文)》 2014年 第8卷 第4期   页码 464-479 doi: 10.1007/s11708-014-0307-9

摘要: Dynamic voltage restorer (DVR) is used to protect sensitive loads from voltage disturbances of the distribution generation (DG) system. In this paper, a new control approach for the 200 kW solar photovoltaic grid connected system with perturb and observe maximum power point tracking (MPPT) technique is implemented. Power quality improvement with comparison is conducted during fault with proportional integral (PI) and artificial intelligence-based fuzzy logic controlled DVR. MPPT tracks the actual variable DC link voltage while deriving the maximum power from a photovoltaic array and maintains DC link voltage constant by changing modulation index of the converter. Simulation results during fault show that the fuzzy logic based DVR scheme demonstrates simultaneous exchange of active and reactive power with less total harmonic distortion (THD) present in voltage source converter (VSC) current and grid current with fast tracking of optimum operating point at unity power factor. Standards (IEEE-519/1547), stipulates that the current with THD greater than 5% cannot be injected into the grid by any distributed generation source. Simulation results and validations of MPPT technique and operation of fuzzy logic controlled DVR demonstrate the effectiveness of the proposed control schemes.

关键词: fuzzy logic     maximum power point tracking (MPPT)     proportional integral (PI)     control     voltage restorer    

Reactive power deployment and cost benefit analysis in DNO operated distribution electricity markets with D-STATCOM

Atma Ram GUPTA,Ashwani KUMAR

《能源前沿(英文)》 2019年 第13卷 第1期   页码 86-98 doi: 10.1007/s11708-017-0456-8

摘要: The aim of this paper is to analyze unbalanced radial distribution systems (UBRDS) with the distribution static compensator (D-STATCOM). The main objectives of this paper are D-STATCOM allocation in UBRDS with an objective of providing reactive power support to enhance voltage profile and reduce line losses of the distribution network, determination of optimal D-STATCOM rating subjected to minimization of total cost, and impact of D-STATCOM placement on improving power factor and savings in cost of energy loss. The analysis is conducted on a large industrial load model with light, medium and high loading scenarios. Further, the impact of load growth is also considered for better planning of the power distribution system. The results are obtained on standard 25-bus UBRDS to check the feasibility of the proposed methodology.

关键词: unbalanced distribution system     D-STATCOM     voltage sensitivity index     load models     load growth     distribution network operator (DNO)    

Power quality investigation of a solar PV transformer-less grid- connected system fed DVR

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

《能源前沿(英文)》 2014年 第8卷 第2期   页码 240-253 doi: 10.1007/s11708-014-0322-x

摘要: This paper presents a single stage transformer-less grid-connected solar photovoltaic (PV) system with an active and reactive power control. In the absence of active input power, the grid-tied voltage source converter (VSC) is operated in a reactive power generation mode, which powers the control circuitry, and maintains a regulated DC voltage to the VSC. A data-based maximum power point tracking (MPPT) control scheme which performs power quality control at a maximum power by reducing the total harmonic distortion (THD) in grid injected current as per IEEE-519/1547 standards is implemented. A proportional-integral (PI) controller based dynamic voltage restorer (DVR) control scheme is implemented which controls the grid side converter during single-phase to ground fault. The analysis includes the grid current THD along with the corresponding variation of the active and reactive power during the fault condition. The MPPT tracks the actual variable DC link voltage while deriving the maximum power from the solar PV array, and maintains the DC link voltage constant by changing the modulation index of the VSC. Simulation results using Matlab/Simulink are presented to demonstrate the feasibility and validations of the proposed novel MPPT and DVR control systems under different environmental conditions.

关键词: data-based maximum power point tracking (MPPT)     total harmonic distortion (THD)     proportional integral     control     voltage restorer     pulse width modulation    

Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

《能源前沿(英文)》 2023年 第17卷 第3期   页码 446-446 doi: 10.1007/s11708-022-0851-7

摘要: Owing to increased penetration of three-phase and single-phase microgrids, distributed energy resources (DERs), and responsive loads, the maintenance of a three-phase balance by distribution networks is a significant challenge. Existing literature on distributed energy management for networked microgrids generally neglects the distribution network or employs a simplified phase balanced distribution network; thus, these evaluations are not applicable. Further, the underlying mutual coupling between the different phases of distribution feeders results in a more challenging situation. To solve this issue, this study sought to propose distributed energy management based on a three-phase unbalanced distribution network. Various three-phase or single-phase microgrids, utility-owned DERs, and responsive loads were coordinated through iteratively adjusted price signals. Based on the price signals received, the microgrid controllers (MCs) and distribution management system (DMS) updated the schedules of the DERs and responsive loads under their jurisdiction separately. The price signals were then updated according to the generation-load mismatch at each node and distributed to the corresponding MCs and DMS for the next iteration. The iteration continued until a sufficiently small generation-load mismatch was achieved at all nodes, that is, a balanced generation and load at all nodes under the agreed price signals. Considering a three-phase unbalanced distribution network, the price signals were determined per phase per node. Overall, the proposed distributed energy management coordinates microgrids, utility-owned DERs, responsive loads with guaranteed network constraints, and preserves the privacy of microgrid customers. This distributed energy management method was further demonstrated through various case studies on a three-phase networked microgrid test system.

关键词: distributed optimization     energy management     networked microgrids     three-phase distribution network     distributed energy resources    

switched fractional controller for performance improvement of single phase active power filter under unbalanced

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

《能源前沿(英文)》 2016年 第10卷 第2期   页码 203-212 doi: 10.1007/s11708-015-0381-7

摘要: A novel controller is proposed to regulate the DC-link voltage of a single phase active power filter (SPAPF). The proposed switched fractional controller (SFC) consists of a conventional PI controller, a fractional order PI (FO-PI) controller and a decision maker that switches between them. Commonly, the conventional PI controller is used in regulation loops due to its advantages in steady-state but it is limited in transient state. On the other hand, the FO-PI controller overcomes these drawbacks but it causes dramatic degradation in control performances in steady-state because of the fractional calculus theory and the approximation method used to implement this kind of controller. Thus, the purpose of this paper is to switch to the PI controller in steady-state to obtain the best power quality and to switch to the FO-PI controller when external disturbances are detected to guarantee a fast transient state. To investigate the efficiency and accuracy of the SFC considering all robustness tests, an experimental setup has been established. The results of the SFC fulfill the requirements, confirm its high performances in steady and transient states and demonstrate its feasibility and effectiveness. The experiment results have satisfied the limit specified by the IEEE harmonic standard 519.

关键词: conventional PI controller     fractional calculus (FC)     total harmonic distortion (THD)     Oustaloup continuous approximation (OCA)     single phase active power filter (SPAPF)    

Experimental and theoretical investigations of the lateral vibrations of an unbalanced Jeffcott rotor

Ali ALSALEH, Hamid M. SEDIGHI, Hassen M. OUAKAD

《结构与土木工程前沿(英文)》 2020年 第14卷 第4期   页码 1024-1032 doi: 10.1007/s11709-020-0647-y

摘要: The current work experimentally explores and then theoretically examines the lateral vibrations of an unbalanced Jeffcott rotor-system working at several unbalance conditions. To this end, three conditions of eccentric masses are considered by using a Bently Nevada RK-4 rotor kit. Measurements of the steady-state as well as the startup data at rigid and flexible rotor states are captured by conducting a setup that mimics the vibration monitoring industrial practices. The linear governing equation of the considered rotor is extracted by adopting the Lagrange method on the basis of rigid rotor assumptions to theoretically predict the lateral vibrations. The dynamic features of the rotor system such as the linearized bearing induced stiffness are exclusively acquired from startup data. It is demonstrated that, with an error of less than 5%, the proposed two-degrees-of-freedom model can predict the flexural vibrations at rigid condition. While at flexible condition, it fails to accurately predict the dynamic response. In contrast to the other works where nonlinear mathematical models with some complexities are proposed to mathematically model the real systems, the present study illustrates the applicability of employing simple models to predict the dynamic response of a real rotor-system with an acceptable accuracy.

关键词: rotor-dynamics     Jeffcott rotor     lateral vibrations     Lagrange method     system-equivalent stiffness     sleeve bearings     oil film induced stiffness    

Recent advances toward high voltage, EC-free electrolytes for graphite-based Li-ion battery

Tong Zhang, Elie Paillard

《化学科学与工程前沿(英文)》 2018年 第12卷 第3期   页码 577-591 doi: 10.1007/s11705-018-1758-z

摘要:

Lithium-ion batteries are a key technology in today’s world and improving their performances requires, in many cases, the use of cathodes operating above the anodic stability of state-of-the-art electrolytes based on ethylene carbonate (EC) mixtures. EC, however, is a crucial component of electrolytes, due to its excellent ability to allow graphite anode operation–also required for high energy density batteries–by stabilizing the electrode/electrolyte interface. In the last years, many alternative electrolytes, aiming at allowing high voltage battery operation, have been proposed. However, often, graphite electrode operation is not well demonstrated in these electrolytes. Thus, we review here the high voltage, EC-free alternative electrolytes, focusing on those allowing the steady operation of graphite anodes. This review covers electrolyte compositions, with the widespread use of additives, the change in main lithium salt, the effect of anion (or Li salt) concentration, but also reports on graphite protection strategies, by coatings or artificial solid electrolyte interphase (SEI) or by use of water-soluble binder for electrode processing as these can also enable the use of graphite in electrolytes with suboptimal intrinsic SEI formation ability.

关键词: lithium-ion     electrolyte     solid electrolyte interphase     additives     high voltage     graphite    

Development and advances in modular multilevel converter based HVDC projects in China

《工程管理前沿(英文)》   页码 183-189 doi: 10.1007/s42524-022-0248-7

摘要: . {{custom_ra.content}} . . . {{article.highlightEn}} . . . {{article.abstractEn}} . . . {{article.authorSummayEn}} . . . . .

关键词: high voltage direct current     power converter     power systems     renewable energy     ultra-high voltage    

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

《能源前沿(英文)》 2013年 第7卷 第3期   页码 358-372 doi: 10.1007/s11708-013-0257-7

摘要: Efficient utilization of energy resources is essential for a developing country like India. The concept of smart grid (SG) can provide a highly reliable power system with optimized utilization of available resources. The present Indian power grid requires revolutionary changes to meet the growing demands and to make the grid smarter and reliable. One of the important requirements for SG is the instantaneous monitoring of the voltage, current and power flows at all buses in the grid. The traditional monitoring system cannot satisfy this requirement since they are based on nonlinear power flow equations. Synchro-phasor-measurement devices like phasor measurement units (PMUs) can measure the phasor values of voltages at installed buses. Consequently, the currents passing through all branches connected to that bus can be computed. Since the voltage phasor values at the neighboring buses of a bus containing the PMU can be estimated using Ohm’s law, it is redundant to install PMUs at all the buses in a power grid for its complete observability. This paper proposes the optimal geographical locations for the PMUs in southern region Indian power grid for the implementation of SG, using Integer Linear Programming. The proposed optimal geographical locations for PMU placement can be a stepping stone for the implementation of SG in India.

关键词: phasor measurement units (PMUs)     smart grid (SG)     southern region Indian power grid (SRIPG)     integer linear programming (ILP)    

标题 作者 时间 类型 操作

Multiple target implementation for a doubly fed induction generator based on direct power control under unbalancedand distorted grid voltage

Heng NIAN,Yi-peng SONG

期刊论文

Power quality improvement using fuzzy logic controller for five-level shunt active power filter under distortedvoltage conditions

Amar BENAISSA,Boualaga RABHI,Ammar MOUSSI

期刊论文

Experimental investigation and comparative study of inter-turn short-circuits and unbalanced voltage

Fatima BABAA, Abdelmalek KHEZZAR, Mohamed el kamel OUMAAMAR

期刊论文

Analysis and stabilization control of a voltage source controlled wind farm under weak grid conditions

期刊论文

Performance investigation of artificial intelligence based controller for three phase four leg shunt active filter

J. JAYACHANDRAN,R. MURALI SACHITHANANDAM

期刊论文

Parameter identification of interconnected power system frequency after trip-out of high voltage transmission

Xuzhan ZHOU,Shanshan LIU,Mingkun WANG,Yiping DAI,Yaohua TANG

期刊论文

THD reduction with reactive power compensation for fuzzy logic DVR based solar PV grid connected system

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

期刊论文

Reactive power deployment and cost benefit analysis in DNO operated distribution electricity markets with D-STATCOM

Atma Ram GUPTA,Ashwani KUMAR

期刊论文

Power quality investigation of a solar PV transformer-less grid- connected system fed DVR

Akhil GUPTA,Saurabh CHANANA,Tilak THAKUR

期刊论文

Distributed energy management for networked microgrids in a three-phase unbalanced distribution network

期刊论文

switched fractional controller for performance improvement of single phase active power filter under unbalanced

H. AFGHOUL,F. KRIM,D. CHIKOUCHE,A. BEDDAR

期刊论文

Experimental and theoretical investigations of the lateral vibrations of an unbalanced Jeffcott rotor

Ali ALSALEH, Hamid M. SEDIGHI, Hassen M. OUAKAD

期刊论文

Recent advances toward high voltage, EC-free electrolytes for graphite-based Li-ion battery

Tong Zhang, Elie Paillard

期刊论文

Development and advances in modular multilevel converter based HVDC projects in China

期刊论文

Optimal placement of PMUs for the smart grid implementation in Indian power grid—A case study

Pathirikkat GOPAKUMAR, G. Surya CHANDRA, M. Jaya Bharata REDDY, Dusmata Kumar MOHANTA

期刊论文